Temperature Sensors
Balco 1000 Ohm at 21.1 °C sensing element - for KX436 and CX528 controllers.
MODEL
DESCRIPTION
SBA /
S13x
Room sensor - IP30
SBA55 /
S14x
Room sensor with set-point adjustment potentiometer 5 to 35°C - IP30 protection
SBC
Immersion - AISI 304 stainless steel well- 1/2”gas nickel-plated brass connection length 113 mm -
PG9 cable sleeve - max fluid temperature: 140 °C - IP44 - supplied with brass pocket
SBD
Duct - with mounting flange - 7.5 mm - length 300 mm - PG9 cable sleeve,max fluid temperature:
95 °C - IP44
SBE
Outside - PG9 cable sleeve - IP44
SBF
Strap-on ( immersion) - IP44
SBV
As SBD but with uncovered fast-detecting sensing element - length 315 mm, max fluid tempera-
ture: 65 °C - IP44
Not suitable for applications with possible condensation
421
Well for SBC and SPTC-C with AISI 304 stainless steel connection
Temperature Sensors
PTC 1K (SPTC) and PT100 (SPTX-Uonly) sensing element for Omnia and CTY-TX controllers.
MODEL
DESCRIPTION
SPTC-A /
S23x
Room sensor for Omnia controllers - IP30
SPTC-A5 /
S22x
Room sensor for Omnia with set point adjustment - IP30
SPTC-A6 /
S21x
Room sensor for Omnia with 10-30 °C degree scale - IP30
SPTC-C Immersion sensor for CTYxx1 and Omnia cable type, 1.5 m silicone cable
SPTC-CR
Immersion sensor for CTYxx1 and Omnia with case and stick enclosed - supplied with brass po-
cket
SPTC-D Duct sensor for CTYxx1 and Omnia,cable type, 1.5 m silicone cable
SPTC-E
Outside sensor for Omnia with PG9 cable sleeve - IP44
SPTC-F
Strap-on pipe sensor for Omnia - IP44
SPTC-V
As SPTC-D but with case and stick enclosed for Omnia and CTYxx1 - length 315 mm - max tem-
perature 65 °C - IP44
Not suitable for applications with possible condensation
SPTX-U Universal sensor for CTYxx2, PT100 sensing element, cable type, 3 m cable
Temperature Sensors
NTC sensing element : STA/STR, 5 K Ohm at 25°C, STR72 10 Kohm at 25 °C, STR73 33
Kohm at 25°C - Application range 0 to 50 °C.
MODEL
DESCRIPTION
STA71 /
S33x
Room sensor with set point adjustment 5 to 35°C for NR7000 - IP30
STA75S /
S32x
Room sensor with set point adjustment 5 to 35°C 3K for NR7000 - IP30
STA80S /
S34x
Room sensor with set point adjustment 3 K - on/off and fan speed selector for NR7000 - IP30
STR71
Return air sensor with mounting kit for terminal unit for NR7000 - IP30
STR72
Return air or pipe-contact sensor without mounting kit for RA735 - IP30
STR73
Return air or pipe-contact sensor without mounting kit for AX526/527/536/537 - IP30